Rugged, Affordable, Professional Testsets

Testset Specifications - HD-4


 

ELECTRICAL

 

Talk Mode:

 

Loop Limit:

8000 Ohms max at 48 VDC

 

20 Mi. @ 22 Ga., 9 Mi. @ 26 Ga.

Monitor Mode:

 

Leakage:

Higher than 500K Ohms

Impedance:

Greater than 120K Ohms

Return Loss @ 600 Ohms:

Greater than 14dB from 300 to 3400 Hz


ROTARY DIAL OUTPUT

 

Pulse Rate:

10 pps +/- 10 %

M/B Ratio:

60/40% +/- 2%

Inter-digit Interval:

800 ms typical

Leakage During Break:

Greater than 100KOhms

 

Less than 1 mA


DTMF OUTPUT

 

Tone Frequency Error:

+/- 1.5% maximum

Tone Level:

 

   High group:

- 6 dBm +/- 2dB

   Low group:

- 8 dBm +/- 2dB

High/Low Tone - twist:

2 dB +/- 1 dB


MEMORY DIALING

 

Types:

Last number redial

Mode:

Tone and pulse

Retention:

15 minutes

 

 

Capacity:

23 digits

 

 

 

 


RINGER

 

Output level:

76 dBA at 1 meter

Response:

16 - 25 Hz. 60 Volts

Operating Temperature:

-10 to +60 Deg. C.


PHYSICAL

 

Length:

9 3/4 inches (24.76 cm)

Width:

2 5/8 inches (6.66 cm)

Height:

2 1/2 inches (6.35 cm)

Weight:

15 ounces (425 grams)

 

 


Specifications subject to change without notice.

 

 

 
 

 

 



HD Telecom, Inc.
2629 Redwing Road, Suite 370 • Fort Collins, Colorado 80526
Tel: (970) 416-1343   Fax: (970) 416-1191